Nulleinspeisung Control Script for Hoymiles Wechselrichter with OpenDTU and Shelly3EM Pro
Originally forked from: https://github.com/Selbstbau-PV/Selbstbau-PV-Hoymiles-nulleinspeisung-mit-OpenDTU-und-Shelly3EM
This script is a modified version, tailored for specific use-cases and enhancements.
All original work and its credits belong to the authors of the referenced repository.
"""
import requests, time, sys
from requests.auth import HTTPBasicAuth
# User Configuration: Replace with your specific details
serial = "<SERIAL_NUMBER>" # Serial number of Hoymiles Wechselrichter
maximum_wr = <MAX_OUTPUT> # Maximum output of the Wechselrichter (Watts)
minimum_wr = <MIN_OUTPUT> # Minimum output of the Wechselrichter (Watts)
# OpenDTU Configuration: Replace with your OpenDTU details
dtu_ip = '<OPEN_DTU_IP>'
dtu_user = '<OPEN_DTU_USERNAME>'
dtu_password = '<OPEN_DTU_PASSWORD>'
# Shelly Device Configuration: Replace with your Shelly 3EM Pro IP
shelly_ip = '<SHELLY_IP>'
while True:
time.sleep(1) # Sleep for 1 second
try:
# Retrieve data from OpenDTU REST API and parse it into JSON format
dtu_response = requests.get(f'http://{dtu_ip}/api/livedata/status/inverters').json()
# Extract specific data from the JSON response
reachable = dtu_response['inverters'][0]['reachable'] # Is DTU reachable?
producing = int(dtu_response['inverters'][0]['producing']) # Is the Wechselrichter producing?
old_limit = int(dtu_response['inverters'][0]['limit_absolute']) # Old limit
power_dc = dtu_response['inverters'][0]['AC']['0']['Power DC']['v'] # DC power from panels
power_ac = dtu_response['inverters'][0]['AC']['0']['Power']['v'] # AC power output to grid (Watts)
except:
print('Error retrieving data from OpenDTU')
try:
# Retrieve data from Shelly 3EM REST API
shelly_response = requests.get(f'http://{shelly_ip}/rpc/Shelly.GetStatus')
if shelly_response.status_code == 200:
shelly_data = shelly_response.json()
total_act_power = shelly_data['em:0']['total_act_power'] # Total active power
else:
print(f"Shelly request failed with status code: {shelly_response.status_code}")
grid_consumption = total_act_power - 100 # Total grid consumption (all phases)
except:
print('Error retrieving data from Shelly Pro3EM')
# Calculate and display power values
print(f'\nGrid Consumption: {round(grid_consumption, 1)} W, Production: {round(power_ac, 1)} W, Total Consumption: {round(grid_consumption + power_ac, 1)} W')
if reachable:
# Calculate new limit in Watts
new_limit = grid_consumption + old_limit - 5
# Check and adjust the new limit against maximum and minimum thresholds
if new_limit > maximum_wr:
new_limit = maximum_wr
print(f'Setpoint to maximum: {maximum_wr} W')
elif new_limit < minimum_wr:
new_limit = minimum_wr
print(f'Setpoint to minimum: {minimum_wr} W')
else:
print(f'Calculated Setpoint: {round(grid_consumption, 1)} W + {round(old_limit, 1)} W - 5 W = {round(new_limit, 1)} W')
# Update the inverter limit if it has changed
if new_limit != old_limit:
print(f'Setting inverter limit from {round(old_limit, 1)} W to {round(new_limit, 1)} W... ', end='')
try:
# Send the new limit to the inverter
dtu_limit_response = requests.post(
url=f'http://{dtu_ip}/api/limit/config',
data=f'data={{"serial":"{serial}", "limit_type":0, "limit_value":{new_limit}}}',
auth=HTTPBasicAuth(dtu_user, dtu_password),
headers={'Content-Type': 'application/x-www-form-urlencoded'}
)
print(f'Configuration sent ({dtu_limit_response.json()["type"]})')
except:
print('Error sending configuration')
sys.stdout.flush() # Flush cached messages to stdout
time.sleep(5) # Sleep for 5 seconds